Specs & Approvals
Specific
SAFE Encasement Systems do fully comply with the following
ASTM Test Standards and have earned the Federal, State
and City approvals listed below. For
more detailed information on what systems were tested,
or to request digital or hard copies of test reports,
please Contact us.
Technical
Data
ASTM E-1795-97,
“Standard Specification for Non-Reinforced Liquid
Coating Encapsulation Products
for Leaded Paint in Buildings”
ASTM E-84-99,
Surface Burning Characteristics, Class I, Flame Spread
Index =10, Smoke Developed
Index = 15, (this is equal to Class A in NFPA 255,
ANSI/UL #723, AND UBC 8-1).
ASTM E-119-98,
Fire Test of encased fireproofing on steel columns,
(3-hour test firing demonstrates
there was no negative effect on encased fireproofing
performance).
ASTM E-1494-92,
Fire Test of encased fireproofing on a steel deck,
(2-hour test firing demonstrated
there was no negative effect on encased fireproofing
performance).
Passed
University of Pittsburgh Combustion Toxicological
Testing Protocol,
(no
acute lethality of thermal decomposition products).
ASTM E-162-98,
Surface Flammability with Radiant Energy Source,
(a DOT Standard) (Fs x
Q=Is) Fs = 1.29 Q=1.77, Is =
2.31
ASTM E-736-93, Passed Cohesion/Adhesion Testing over Fire Proofing.
*ASTM D-3359, Pull-off Adhesion (exceeds standards).
*ASTM D-4214, Chalking (encasement surface does not chalk).
*ASTM D-4060, Dry Abrasion Resistance (exceeds test standards).
*ASTM D-522, Flexibility (remains flexible over time does not become brittle and crack).
*ASTM D-2794, Impact Resistance (160+in.lbs. - exceeds testing standard).
*ASTM D-3273, D-3274, Mildew Resistance (passed).
*ASTM D-3359, Paint-ability (passed, can be over painted).
*ASTM D-2486, Scrub Resistance (exceeded 1200+ cycles test limit).
*ASTM D-2370, Tensile Properties of Encasement System (245 psi).
*ASTM D-3960, Zero VOC’s (below 25 ppm detection limit for specified test method).
*ASTM D-1653, Permeability (0.6 perms), water vapor can pass through the multi-layered protective
membrane formed through the encasement process (“lets the building breathe”).
*ASTM D-1308, Household Chemical & Water Resistance
(exceeded the standards on all tests).
*ASTM G-53, Weathering/Aging (1,000 hours) – no chalking, cracking or peeling.
Approvals, Acceptances,
Listings & Additional ASTM Tests
Massachusetts Department of Public Health Approved (Report # DL-12571-A).
Approved in the States of MA, NY, MN, CO, CA, OH and CT
(interior
and exterior protocol in CT).
Approved by the City of Los Angeles, CA.
UL Listed Surface (file # R16588).
Listed with the CA Fire Marshall’s Office.
Approved and Listed by the City of New York, MEA# 301-00-M.
Other approvals or acceptances include; DOD, US Army Corps
of Engineers, NEHC and the
US Department of Agriculture (US Forestry).
ASTM B-117 Salt Fog Chamber (no blistering or rusting
after 1,500 hours of exposure).
ASTM D-4585 Humidity Chamber (no blistering or rusting
after 1,400 hours of exposure).
Federal Standard TT-C-555B - Wind Blown Rain Test.
DL Labs Pull-Off Strength Report
|